    A SUCCESSFUL EVENT AT THE

    IEC TC 37/SC 37A PLENARY MEETING IN MILAN BY ZOTUP S.r.l.

    Read more in the  COMPANY NEWS

    Leonardo Tour 16 300px

  •  

    DO YOU KNOW HOW TO CHOOSE THE RIGHT SPD?

       Download our WEBAPP free of charge

    webapp gallery en 1

  • 1
  • 2
  • Default
  • Title
  • Date
  • Random
  • Now available for download the CATALOGUE ZOTUP 2020/2021, with new products and interesting news about SPDs. 

    +
  • Find the proper Surge Protection Device
    Download the New ZOTUP Webapp
    FOR FREE

    +
  • Visit our Facebook fanpage .... you'll discover events, news and updates. Stay tuned!!

    +
  • ZOTUP is a new SPD with progressive indication of performance. It's easier to control progressively the SPD level of efficiency and then to plan its replacement. 

     

    +
  • Give a look to the new video preview. ZOTUP a brand new range!

    +
  • ZOTUP is the new SPD that allows you not to use fuses for a quicker and easier setup.

     

    +

Surge Arrester for High Voltage Systems

ZOTUPHV

 

Lightning surge counter models ZU SC and ZU SC-M

Lightning surge counter models ZU SC and ZU SC-M

In compliance with the standards IEC/EN 62561-6.
The installation of the lightning surge counter must be combined with a surge arrester mounted with an insulating support.
Lightning surge counters do not require a power supply, they are installed at the earth/ground terminal of a single surge arrester or at the common earth/ground connection of a group of arresters.
The ZU SC model is capable of counting surges to ground.
The ZU SC-M model counts surges to ground and provides an indication of the total leakage current via an analogue meter.
A significant change in the value of the indicated current after installation shows a deterioration of the surge arrester or an increased level of pollution on surface insulator of the surge arrester.
Both models can be supplied, upon request, with an auxiliary contact for the remote monitoring of the counting.

Data sheet ZU SC and ZU SC-M

105 000 106 000 105 001 106 001 ZU SC ZU SC M

Surge Arrester for High Voltage Systems

ZOTUPHV

Insulating bracket model ZU 7

Insulating bracket model ZU 7

This insulating support is necessary to support the lower arrester end, when the disconnector device model ZU 4 is applied. This fixes the arrester and avoids leakage currents to ground.

Data sheet ZU 7

107 000 104 000 ZU 7 

Surge Arrester for High Voltage Systems

ZOTUPHV

medium voltage spd ZU MV DC

ZU HV DC is a surge arrester with typical usage in direct current systems and particularly where electric traction (railway, underground) is used.

It provides the following features and benefits:

  • Surge arrester type L with: limiting operation, varistor for protection against overvoltages in direct current applications, and atmospheric lightning strikes;
  • This SPD is Installed in a vertical position, when hooked on overhead lines and when mounted on electric motors;
  • Its high mechanical resistance to bumps and vibrations complies with the regulations of IEC/EN 60068 part 2-29;
  • Its silicone rubber housing with high creepage distance allows internal or external mounting;
  • Its high discharge capacity In is 10 kA (8/20);
  • Its continuous voltage rating is from 1 to 4kV d.c.;
  • Size and volume of the surge arresters based on the practical minimum for each nominal voltage;
  • The insulator of the surge arrester is characterized by the absence of junction lines;
  • The construction and manufacturing process prevent partial discharges;
  • Sealed with aluminium fittings and terminead with stainless steel clamps, screws and washers.

Data sheet ZU HV DC

110 001 110 002 110 003 110 004 ZU HV DC-1

 

110 001 110 002 110 003 110 004 ZU HV DC-2TAB

Surge Arrester for High Voltage Systems

ZOTUPHV

medium voltage spd zu 4

Disconnector device model ZU 4

Surge arresters for medium voltage systems are often equipped with a disconnector that permits the disconnection of the surge arrester in case of an internal fault. This disconnection prevents a persistent fault in the network and provides a visual indication that the surge arrester is defect. The disconnector is activated by an increase in internal pressure due to the electrical arc caused by the sublimation of the internal connecting wire as a result of the fault current. The operating mechanism is very reliable and the characteristc remains constant even over long time.

NOTE: It is important to ensure that sufficient insulating distance is kept for parts remaining energised after the detachment of the lower part of the disconnector.

Data sheet ZU 4

107 000 104 000 ZU 4